Sekonic DIGI MASTER L-718 Betriebsanleitung Seite 14

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 16
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 13
Contrast Metering for Lighting Balance
When calculating a desired lighting balance, DIGI MASTER can be used
to measure the brightness of main and fill-in lightings from the subject
position.
(1) Mount the Lumidisc instead of
Lumisphare for usual incident light
measurement.
(2) Select the measuring mode, and set
the ISO sensitivity and shutter speed
(T) as shown in the paragraphs for
“Preparing the Meter for Operation”.
(3) Point the center of Lumidisc
accurately toward the center of axis
of the main lighting source from the
subject, and measure the light
according to the measuring method
for the respective mode.
(4) Using the same procedure, measure
the fill-in light(s). In this case, be sure
that the meter is held so that it is not
influenced by the main lighting
source.
(5) The F-stop difference between the
main and fill-in lighting sources is
lighting contrast ratio (Table 1).
< NOTE >
In case of the measurement for F-
stop value, memory display
function (refer to page 20) is useful
for this metering.
Difference in Contrast ratio
exposure reading
1 2 : 1
1 1/2 3 : 1
2 4 : 1
3 8 : 1
4 16 : 1
5 32 : 1
(Table 1)
Illuminance (Lux) Measurement
DIGI MASTER can be used as an expendient Lux meter when used with
the Lumidisc in ambient light measurement mode.
(2) Set the ISO sensitivity to ISO 100.
(3) Press the F/EV selection key
and select EV mode.
(4) Hold the meter so that the Lumidisc
is parallel to the plane to be
measured, and press the
measuring switch.
(5) The measured EV value can be
converted to the corresponding Lux
value using the (Table 2).
25
24
Seitenansicht 13
1 2 ... 9 10 11 12 13 14 15 16

Kommentare zu diesen Handbüchern

Keine Kommentare