Sekonic SR-430 Spezifikationen Seite 45

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 76
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 44
-36-
Character codes settable when S1 = 5
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
0
SH
EX
ET
AK
BL
BS
HT
LF
HM
CL
SO
SI
1
D2
NK
SN
EB
EM
SB
EC
2
,
.
3
4
5
_
Upper 4 bit
Lower 4 bit
-8 CAN Command (Reset Command)
[Explanation]
This command is used as the reset command. (This command initializes the device.) After this
command is executed, the device is reset internally and returns the ACK code (06H). At the time, the
"READY" LED (green) and "ERROR" LED (red) blink. The host computer must be designed to
transmit the next command after receiving this code.
Separators like STX and ETX can be added by the DC4 command (only in the SR-430 (SR-410
compatible) mode).
[Format]
Host Computer This device
CAN CR Receive
(18H) (0DH)
Reply
ACK
(06H)
9.Control Commands
Seitenansicht 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 75 76

Kommentare zu diesen Handbüchern

Keine Kommentare